These devices are characterized by their high rating 800 a to 6300 a, and their location at the head of the lv installation, generally directly. The purpose of discrimination is to disconnect only the faulty circuit from the distribution network while maintaining the upstream electrical installation active. The circuit breakers located furthest downstream in the installation should be selected and set in order to trip as quickly as possible, so as to limit the. Circuit breaker selections for low voltage installation. The ideal time to complete a discrimination study is before ordering the switchboard and panel board circuit breakers. It is used to detect failures and encapsulates the logic of preventing a failure from constantly recurring, during maintenance, temporary external system failure or unexpected system difficulties. A circuit breaker might remain idle for many years, circuit breaker testing is vital to make sure a safe and reliable performance of the circuit. For consulting and plant engineers, protective device coordination software is absolutely critical for ensuring personnel safety and maximizing system uptime. Discrimination is ensured if the ratio between the circuit breaker ratings is greater than 2.
Each circuit breaker contains a range of different settings that can be used to vary the timecurrent curve of the device, as well as allowing for a range of current and time values for the breaker to trip at. Proper wiring of a house or building is imperative to ensure that the structures. Display the timecurrent curves of 1 to 8 circuit breakers. Circuit breakers are manufactured and tested in accordance with the iec 60947 lowvoltage switchgear and controlgear standard. This is a reasonable approach with electrical circuit breakers in buildings, but for software circuit breakers we can have the breaker itself detect if the underlying calls are. Packaged with a host of additional features, this electrical software configuration makes pdc and short circuit analysis a snap. Discrimination as per iec 609472 can be defined as follows. Temcurve 6 allows the user to model combinations of circuit breakers to achieve selectivity. Check the discrimination between two circuit breakers and display their timecurrent curves. It says the discrimination between the circuit breakers is up to 36ka and cascading up to 50ka. A circuit breaker might remain idle for many years. Circuit breaker is a design pattern used in modern software development.
Selective coordination with circuit breakers iaei magazine. How to test a circuit breaker with a voltage tester dummies. Choosing a circuit breaker that trips too late can result in catastrophic damage to machine and cables. Choosing a circuit breaker with a trip curve that trips too soon can result in nuisance tripping. Curves is an instant software for setting the trip characteristics of the protection devices and verifying selectivity between abb circuitbreakers in low voltage. Options include the circuit breaker seminar, client field seminars, committee meetings and conferences, webbased training, users groups. With curveselect you can easily assure the selectivity discrimination of a system. Circuit breaker discrimination for reliable data centre. Curves the abb software for trip characteristics coordination the.
The curve below shows a 90ampere circuit breaker and an upstream 400ampere circuit breaker. The purpose of this cahier technique is to set out the discrimination techniques which apply specifically to low voltage power circuitbreakers. Search all the circuit breakers that can be selective with a defined circuit breaker. The continued commitment customer service, high quality products, and competitive price have advanced circuit breaker warehouse to be southern californias most complete circuit breaker source. This note is an introduction to some circuit breaker concepts and the application of circuit breakers to low voltage power systems. While the iec low voltage circuit breaker standard iec 609472, low voltage switchgear. Coordination between circuitbreakers electrical installation guide. Selective coordination is required for systems related to life safety as defined in the nec, and is achieved when an overcurrent on a circuit is interrupted and only the closest upstream device opens such that only the section of the electrical system with a problem is taken offline. To optimise the cost of the switchboard thanks to protection coordination. The masterpact mtz circuit breaker offers the same legendary performance, with advanced iot connectivity and seamless integration with building and energy management systems through schneider electrics ecostruxure power architecture. Whether you are designing a new installation, expanding an existing one or doing maintenance, electrical calculation tools is a suite of online tools for a quick protection device selection, discrimination checking and cable calculation. Check the discrimination between two circuitbreakers and display their timecurrent curves.
How to use the schneider electric discrimination tool youtube. To get the most out of temcurve 6, nhp recommends attending a temcurve 6 training course which are held periodically at our many. Timecurrent curve of a 160a breaker from powercad software. Discrimination with lv power circuit breakers the purpose of this cahier technique is to set out the discrimination techniques which apply specifically to low voltage power circuit breakers. The purpose of discrimination is to disconnect only the faulty circuit from the. Display the timecurrent curves of 1 to 8 circuitbreakers. Circuit breaker solutions doble engineering company. Discrimination with lv power circuitbreakers electrical. As this curve is reporting the amount of current vs time, it is a. To select new circuitbreakers when discrimination is mandatory. Our software solution helps with energy efficiency elec calc is robust software offers critical calculations for factors such as earthing systems, cable ampacity, short circuit currents, thermal stresses, voltage drops and discrimination studies between protections that. This applies to hv and lv, the illustration below is for a simple singlefeed lv system.
Supply circuit discrimination, compliance checking asnzs3000. This is a type of current based discrimination where in there are two circuit breakers in series, the circuit breaker on the load side effects the protection without causing the upstream circuit breaker to operatetrip. Discrimination is determined by comparing the characteristics of each circuit breaker with those of the protective device circuit breaker or fuse located immediately upstream. Short circuit discrimination is based on the principle that if a fault is close to the main source of supply, the prospective fault current will be higher. Doble offers a variety of circuit breakerrelated training courses and seminars throughout the year. Circuit breaker warehouses capabilities range from single retail store installations to multioutlet chains and major highrise development. The software to view directly coordination between devices. If the selectivity limit current is higher than the maximum shortcircuit current that can occur on the circuit protected by the downstream protective device, discrimination is said to be total for the given installation. Powercad5 electrical engineering design software allows engineers to.
Should a fault occurs downstream, only the circuitbreaker placed immediately upstream from the fault will trip. Selective coordination with circuit breakers photo credit. If that is not an op on, consider having a local vendor test the breakers for you. The range of circuit breakers includes air circuit breakers, moulded case circuit breakers and miniature circuit breakers. Curves could also be checked with curve direct software tools db120590 discrimination between. Every circuit breaker has a characteristic curve that reports the manner in which it trips. How to design an electrical system in which the upstream protective device fuse or circuit breaker nearest to the system fault clears the fault without affecting the protective devices that are upstream from it. Protection discrimination is an essential element that must be taken into account.
Circuit breaker discrimination also known as selectivity is the ability of the local circuit breaker to operate before any upstream circuit breakers under fault conditions. Search all the protections that can be selective with a defined circuitbreaker. Therefore, discrimination can be achieved by setting a circuit breaker to a limit that does not cause unnecessary trips. Cad software and tools the cad software and tools enhance. Knowing how to test a circuit breaker can save on electricians fees. Welcome to the circuit breakers store, where youll find great prices on a wide range of different circuit breakers for your home. I have two circuit breakers, the upstream circuit breaker is rated for currents 100a160a and the downstream circuit breaker is rated for currents up to 25a. We need different trip curves in order to balance the right amount of overcurrent protection against optimal machine operation. Eaton offers you easy to operate support in the selection, engineering and monitoring of circuitbreakers. How to use the schneider electric discrimination tool.
Circuitbreaker discrimination works by comparing the timecurrent curves for the longtime delay releases affected by the fault see fig. Key priorities when making equipment selection decisions include. The technique of cascading uses the properties of currentlimiting circuit breakers to permit the installation of all downstream switchgear. Circuit breaker selections for low voltage installation with. Circuit breaker testing is vital to make sure a safe and reliable performance of the circuit. It is fully featured and extremely easy to use software including fault level calculations and product technical data. Techniques to get selectivity in low and medium voltage. The voltage tester will indicate if the breaker is getting power. If a fuse blows or a breaker trips in one specific room or device, the rest of the home is protected from the issue that caused the reaction.
To display tripping curves and give the discrimination limit. The curve below shows a 90 ampere circuit breaker and an upstream 400 ampere circuit breaker with an. Circuit breaker finder accessory kit, circuit breaker leads, circuit breaker adapters klein tools 69411. Masterpact mtz circuit breakers schneider electric. Supply circuit discrimination, compliance checking as. Electrical calculation tools is a set of 7 computer aided online tools designed to help you. The magnitude of the prospective short circuit current determined by the size of conductors, the capacity of the supply transformer and the distance between the transformer and. Each circuit breaker that passes the test should be. Schneider electric has an excellent piece of software direct curves designed to carry out a discrimination study based on protection device tripping curves. Why are discrimination studies among protections so. For example, schneider electric has an excellent piece of software direct curves designed to carry out a discrimination study based on protection device tripping curves. When discussing power distribution, discrimination also referred to as selectivity is the selection and arrangement of circuit breakers such that in the event of a short circuit or overload in the line, the circuit breaker closest to the short will be tripped and the upstream circuit breakers will remain unaffected. Test the circuit breaker with a voltage tester to see if its faulty. Discrimination guarantees coordination between the operating characteristics of serialconnected circuitbreakers.
If the breaker is faulty, youll need to replace it. This simple circuit breaker avoids making the protected call when the circuit is open, but would need an external intervention to reset it when things are well again. Discrimination between the circuit breaker and the mv fuse is therefore limited to approx. Circuit breaker tester classification short circuit. The new eaton configurator circuit breaker facilitates errorfree selection and ordering of eatons acbs and. This study includes discrimination and coordination of protection between the lv equipment and the protection located upstream of each mvlv. Fuses or circuit breakers are the main sort of protective devices used in homes. Circuit breaker selectivity white paper gamatronic. I dont normally deal with this type of things so i am a bit confused with this issue.
How to achieve selective coordination of circuit breakers. Circuit breaker tester can be classified into two main groups, viz. Tips for a better low voltage protection discrimination study. As regards the real currents circulating in the circuitbreakers. These are performed solely for the purpose of proving the correctness of general design and the results of such tests conducted on a randomly selected breaker, are applicable to all others of identical construction. With masterpact mtz breakers, enhanced connectivity equips you for the future of power distribution. The other circuitbreakers must be capable of withstanding the thermal and electrodynamic stresses related to the passage of the fault current for the intentional iv coordination tables discrimination and backup. Each circuit breaker contains a range of different settings that can be used to vary the timecurrent curve of the device, as well as allowing for a. The new eaton configurator circuit breaker facilitates errorfree selection. Discrimination, or protection system coordinationis an important aspect of an electrical system design that is often overlooked. Testing and exercising circuit breakers pdu cables.